HOME | SERVICES | SAFETY | LINKS | COMPANY | CONTACT   

Accurate and cost effective interface/level measurements are available with Neutron Backscatter. This technology is based on detecting relative differences in hydrogen concentration. High energy neutrons are emitted from the Am-241 source and are scattered back as low energy thermal neutrons. The low energy neutrons are then counted with a neutron detector. Plotting the resulting counts yields subtle differences that represent different types or phases of the material inside the vessel or pipe.

NEUTRON BACKSCATTER TANK APPLICATION
Neutron Backscatter is utilized for numerous types of measurements. One common application is storage tanks (both circular and spherical). Storage tanks are scanned at several points round the circumference in order to develop a profile of the product inside the tank (hydrocarbon, water, sludge, etc.).


click image to enlarge

click image to enlarge

NEUTRON BACKSCATTER EXTENDED APPLICATIONS
• Levels inside vessels and columns
• Catalyst levels in reactors
• Polymer and other types of deposits in piping and
process lines
• Liquid levels in downcomers, distributors, and draw trays
• Calibrate or verify accuracy of existing level guages
• Perform separator studies
• Identify deposits on the shell side of exchangers
• Locate moisture under insulation

Neutron Backscatter has many other applications.
Give us a call to discuss how we can help with your particular situation.
 
© 2010 QuantumTec | QuantumTec is a Trademark of  Quantum Technical Services, Inc.
QuantumTec, Inc. | PO Box 7590 | Pasadena, TX 77058 | Toll-Free 877-461-7200 | Fax 281-461-7209 | email:  info@qtserv.com